12
RPC
Part # Description
ID
Length Particle
Number Flow rate (mL/min)
Maximum
(mm)
(cm) size (µm)
theoretical Range
Max.
pressure
plates
drop (MPa)
22728 ODS-100Z, 100 Å
2.0
3.5
3
≥
4,000
15.0
22729 ODS-100Z, 100 Å
2.0
5.0
3
≥
5,700
15.0
22730 ODS-100Z, 100 Å
2.0
7.5
3
≥
8,600
21.0
22731 ODS-100Z, 100 Å
2.0
10.0
3
≥
11,500
24.0
22732 ODS-100Z, 100 Å
2.0
15.0
3
≥
17,500
24.0
22733 ODS-100Z, 100 Å
2.0
25.0
3
≥
28,000
30.0
22734 ODS-100Z, 100 Å
3.0
2.0
3
≥
2,000
12.0
22735 ODS-100Z, 100 Å
3.0
3.5
3
≥
4,000
12.0
22736 ODS-100Z, 100 Å
3.0
5.0
3
≥
6,000
15.0
22737 ODS-100Z, 100 Å
3.0
7.5
3
≥
9,000
21.0
22738 ODS-100Z, 100 Å
3.0
10.0
3
≥
12,000
24.0
22739 ODS-100Z, 100 Å
3.0
15.0
3
≥
18,000
24.0
22740 ODS-100Z, 100 Å
3.0
25.0
3
≥
29,000
30.0
22741 ODS-100Z, 100 Å
4.6
2.0
3
≥
2,500
12.0
22742 ODS-100Z, 100 Å
4.6
3.5
3
≥
4,500
12.0
22743 ODS-100Z, 100 Å
4.6
5.0
3
≥
6,500
15.0
22744 ODS-100Z, 100 Å
4.6
7.5
3
≥
9,750
21.0
22745 ODS-100Z, 100 Å
4.6
10.0
3
≥
13,500
24.0
22746 ODS-100Z, 100 Å
4.6
15.0
3
≥
19,500
24.0
22747 ODS-100Z, 100 Å
4.6
25.0
3
≥
30,000
30.0
22748 ODS-100Z, 100 Å, pk 3*
2.0
1.0
5
≥
300
28.0
22749 ODS-100Z, 100 Å
2.0
2.0
5
≥
1,000
9.0
22750 ODS-100Z, 100 Å
2.0
3.5
5
≥
2,500
9.0
21460 ODS-100Z, 100 Å
2.0
5.0
5
≥
3,000 0.15 - 0.18
0.22
18.0
22751 ODS-100Z, 100 Å
2.0
7.5
5
≥
5,500
18.0
22752 ODS-100Z, 100 Å
2.0
10.0
5
≥
7,000
18.0
21459 ODS-100Z, 100 Å
2.0
15.0
5
≥
11,000 0.15 - 0.18
0.22
18.0
22753 ODS-100Z, 100 Å
2.0
25.0
5
≥
18,000
18.0
22754 ODS-100Z, 100 Å
3.0
2.0
5
≥
1,200
9.0
22755 ODS-100Z, 100 Å
3.0
3.5
5
≥
3,000
9.0
22756 ODS-100Z, 100 Å
3.0
5.0
5
≥
4,000
12.0
22757 ODS-100Z, 100 Å
3.0
7.5
5
≥
6,000
18.0
22758 ODS-100Z, 100 Å
3.0
10.0
5
≥
8,500
18.0
22759 ODS-100Z, 100 Å
3.0
15.0
5
≥
13,000
18.0
22760 ODS-100Z, 100 Å
3.0
25.0
5
≥
21,000
18.0
22761 ODS-100Z, 100 Å
4.6
2.0
5
≥
1,500
9.0
22762 ODS-100Z, 100 Å
4.6
3.5
5
≥
3,000
9.0
22763 ODS-100Z, 100 Å
4.6
5.0
5
≥
4,500
12.0
22764 ODS-100Z, 100 Å
4.6
7.5
5
≥
7,000
18.0
22765 ODS-100Z, 100 Å
4.6
10.0
5
≥
9,000
18.0
21461 ODS-100Z, 100 Å
4.6
15.0
5
≥
14,000 0.7 - 1.0
1.2
18.0
21462 ODS-100Z, 100 Å
4.6
25.0
5
≥
23,000 0.7 - 1.0
1.2
21.0
TSKgel Guard column products
21997 ODS-100V Guardgel Cartridge, pk 3* 2.0
1.0
3
For all 3 µm ODS-100V 2 & 3 mm ID columns
21453 ODS-100V Guard Cartridge, pk 3*
3.2
1.5
5
For all ODS-100V 4.6 mm ID columns
21841 ODS-100V Guard Cartridge, pk 3*
2.0
1.0
5
For all 5 µm ODS-100V 2 & 3 mm ID columns
21454 ODS-100Z Guard Cartridge, pk 3*
3.2
1.5
5
For all ODS-100Z 4.6 mm ID columns
21996 ODS-100Z Guardgel Cartridge, pk 3* 2.0
1.0
3
For all 3 µm ODS-100Z 2 & 3 mm ID columns
21995 ODS-100Z Guardgel Cartridge, pk 3* 2.0
1.0
5
For all 5 µm ODS-100Z 2 & 3 mm ID columns
*needs cartridge holder
NOTE: Tosoh Bioscience offers guard columns and guard cartridges to protect your analytical column. Guard cartridges are usually delivered in packages of three and require the appropriate cartridge holder. In general
cartridges for 4.6 mm ID columns are produced in 3.2 mm ID and 1.5 cm length. They require the cartridge holder 19018. Guard cartridges for 2 mm ID columns are 2 mm ID x 1 cm L and require holder 19308.