Home  
  What's New  
  Products  
  Service/Support  
  About Us  
  Literature/Applications  
  Legal Terms  
  Sitemap  
  Search  
search
Tosoh Bioscience GmbH: The Chemistry of Innovation
Gel Filtration Chromatography
TSK-GEL Columns
TSKgel SW
TSKgel SWXL
TSKgel G2000SWxl
TSKgel G3000SWxl
TSKgel G4000SWxl
TSKgel SuperSW
TSKgel UltraSW


Protein Calibration curves for TSKgel SWXL columns

TSKgel SWXL columns, introduced in 1987, represent the 2nd generation of high performance Gel Filtration columns that have become synonymous with analyzing protein molecular weights in the emerging field of biotechnology.

Particle Characteristics
TSKgel SWXL columns contain smaller particles than SW columns; 5 and 8 µm versus 10 and 13 µm. As the TSKgel SW-type columns, TSKgel SWXL columns feature highly porous silica particles, the surface of which has been shielded from interacting with proteins by derivatization with ligands containing diol functional groups. TSKgel SWXL columns stand out from other silica- or polymer-based high performance size exclusion columns by virtue of their large pore volumes. These columns are commonly used in the quality control of monoclonal antibodies and other biopharma products.

Calibration Curves
The figure to the right shows the calibration curves for globular proteins, polyethylene oxides and dextrans for each of the three TSKgel SWXL columns. The following table summarizes the molecular weight ranges for TSKgel G2000SWXL, TSKgel G3000SWXL and TSKgel G4000SWXL columns for globular proteins, polyethylene oxides and dextrans that can, at least partially, access the pores. For comparative purposes, similar data is provided as well for TSKgel SW and TSKgel SuperSW columns.

  Properties and separation ranges for TSKgel SW-type packings 
    (Molecular Weight in Da)
TSKgel packing Particle
size (µm)
Pore size
(Å)    
Globular proteins    
Dextrans 

Polyethylene glycols and oxides

TSKgel  SuperSW2000 4 125 5,000 - 1.5 x 10^5 1,000 - 3 x 10^4 500 - 15,000


TSKgel  G2000SWxl/
TSKgel  BioAssist G2SWxl
5 125 5,000 - 1.5 x 10^5 1,000 - 3 x 10^4 500 - 15,000


TSKgel QC-PAK GFC200 5 125 5,000 - 1.5 x 10^5 1,000 - 3 x 10^4 500 - 15,000


TSKgel  G2000SW 10, 13 125 5,000 - 1 x 10^5 1,000 - 3 x 10^4 500 - 15,000


 
TSKgel  SuperSW3000


4 250 1 x 10^4 - 5 x 10^5 2,000 - 7 x 10^4 1,000 - 3.5 x 10^4
TSKgel  G3000SWxl/
TSKgel  BioAssist G3SWxl
5 250 1 x 10^4 - 5 x 10^5 2,000 - 7 x 10^4 1,000 - 3.5 x 10^4

TSKgel QC-PAK GFC300 5 250 1 x 10^4 - 5 x 10^5 2,000 - 7 x 10^4 1,000 - 3.5 x 10^4


TSKgel  G3000SW 10 250 1 x 10^4 - 5 x 10^5 2,000 - 7 x 10^4 1,000 - 3.5 x 10^4


 
TSKgel  G4000SWxl/
TSKgel  BioAssist G4SWxl
8 450 2 x 10^4 - 7 x 10^6 4,000 - 5 x 10^5 2,000 - 2.5 x 10^5


TSKgel  G4000SW 13, 17 450 2 x 10^4 - 7 x 10^6 4,000 - 5 x 10^5 2,000 - 2.5 x 10^5


Data generated using the following conditions:
Columns: Two 4 µm, 4.6 mm ID x 30 cm L TSKgel SuperSW columns in series; two 5 µm, 7.8 mm ID x 30 cm L TSKgel SWXL columns in series; two 10 µm, 7.5 mm ID x 60 cm L TSKgel SW columns in series
Elution: Globular proteins: 0.3 M NaCl in 0.1 M (0.05 M for TSKgel SWXL columns) phosphate buffer, pH 7.0
Dextrans and polyethylene glycols and oxides (PEOs): distilled water



General Principles of
Chromatography - Mode Poster


Characterizing Biotherapeutics with HPLC - smart solutions for large molecules - Application note

Return to Size Exclusion main page
Tosoh Bioscience GmbH Zettachring 6, 70567 Stuttgart, Germany  Tel: +49-711-132570  Email: info.tbg@tosoh.com