Tosoh Bioscience GmbH: The Chemistry of Innovation
Gel Permeation Chromatography
TSK-GEL Columns
TSKgel Hxl
TSKgel Hhr
TSKgel SuperH
TSKgel SuperHZ
TSKgel SuperHZ1000
TSKgel SuperHZ2000
TSKgel SuperHZ2500
TSKgel SuperHZ3000
TSKgel SuperHZ4000
TSKgel SuperHZM-H
TSKgel SuperHZM-M
TSKgel SuperHZM-N
TSKgel SuperMultipore


The TSKgel SuperHZ column line consists of five columns with different pore sizes, TSKgel SuperHZ1000 through TSKgel SuperHZ4000, and three columns with an extended linear range of the calibration curve, TSKgel SuperHZM-N, TSKgel SuperHZM-M and TSKgel SuperHZM-H. The calibration curves are shown below.

Calibration curves for TSKgel SuperHz columns


Main characteristics for SuperHZ-type columns are:

  • TSKgel SuperHZ columns have been developed for High Throughput, High Efficiency GPC applications such as those encountered in combinatorial chemistry experiments.
  • The benefits of TSKgel SuperHZ columns over conventional Hxl columns are shown in the following chromatogram.
  • Ultra-low sample adsorption, i.e., the columns show true size exclusion behavior for most polymers
  • Maximum operating temperature for TSKgel SuperHZ-type columns is 60°C for TSKgel SuperHZ1000, SuperHZ2000, SuperHZ2500 and SuperHZ3000, and 80°C for the remaining columns in the product line. See TSKgel SuperH-type columns for operating temperatures of 140°C.
  • Limited solvent range. The columns are shipped in THF, which can be exchanged for a limited number of organic solvents as shown below.

Beware of extra-column bandbroadening

Column dimensions are 6 mm ID x 15 cm L and 4.6 mm ID x 15 cm L versus 7.8 mm ID x 30 cm L for conventional GPC columns. The smaller column dimensions translate to a reduction of peak volume by a factor of 3.4 (6 mm ID) and a factor of 5.8 (4.6 mm ID) versus the same component eluting from a corresponding TSKgel Hxl column. Thus, your HPLC system may require optimization of components that can give rise to extra-column bandbroadening, such as connecting tubing, injector, injection volume, detector cell volume, and detector time constant.

Columns with linear calibration curves

The TSKgel SuperHZ product line contains three linear, or mixed-bed columns, in which particles with different pore sizes are blended to provide an extended linear calibration curve. The mixed-bed columns feature increasing linear calibration ranges, from TSKgel SuperHZM-L, SuperHZM-N, SuperHZM-H.

  Solvent compatibility for TSKgel SuperHZ and Hxl columns
The column shipping solvent limits the types of solvents that can be used with each column type.

Column type Shipping solvent* Can be replaced with

TSKgel SuperHZ and Hxl1

Tetrahydrofuran2,3

benzene, chloroform, toluene, xylene, dichloromethane, dichloroethane

Acetone**

carbon tetrachloride4, o-dichlorobenzene, dimethylformamide, dodecane, dimethyl sulfoxide, dioxane, ethylacetate, FC-113, hexane, pyridine, hexafluoroisopropanol/chloroform, methyl ethyl ketone, quinoline, cyclohexane

Chloroform**

m-cresol in chloroform, up to 10% hexafluoroisopropanol/chloroform

Dimethylformamide

dimethyl sulfoxide, dioxane, tetrahydrofuran, toluene

o-Dichlorobenzene

1-chloronaphthalene, trichlorobenzene

Notes:
1) In case of TSKgel SuperHZ and Hxl, keep flow rate below <0.5 mL/min during solvent change. Solvent can be changed one way/one time only.
2) All TSKgel Hxl, Hhr, SuperHZ and SuperH analytical columns are shipped containing tetrahydrofuran (THF), except High Temperature (HT) columns, which contain o-dichlorobenzene.
3) THF in TSKgel G1000Hxl columns cannot be replaced with dichloromethane or dichloroethane.
4) Prolonged exposure to carbon tetrachloride can corrode the stainless steel parts of a column and an HPLC system.
*  100% methanol cannot be used with H-type columns; use this solvent with TSKgel SW-type or Alpha-type columns.
** TSKgel H columns may be specially ordered with this shipping solvent.

   Recommended Solvents by Application for TSKgel H-type columns

Recommended solvent

Application

THF

polystyrene, epoxy resin, phenoxy resin, polycarbonate, polyisoprene, polyvinyl acetate, polyvinyl chloride, monoglycerides, fatty acids, polybutadiene, poly(methyl methacrylate), poly(styrene-butadiene), poly(styrene-acrylonitrile)

N,N-Dimethylformamide (DMF) +/- 5 mM LiBr

polyvinyl chloride, polyvinyl fluoride, urea resins, polyurethane, polystyrene, polyester, polyimido ether, polyimido ester, polyphenol (aqueous solution), polyacrylonitrile

o-Dichlorobenzene (ODCB)

polyethylene, polypropylene

Chloroform

polycarboxylic ether, acrylic resin, epoxy resin, polystyrene

m-Cresol/Chloroform

nylon, polyseter, polyamide, poly(ethylene terephthalate)

Toluene

polybutadiene, polysiloxane


EcoSEC SEC/GPC System

Search the Tosoh HPLC Application Database

Technical support

General Principles of
Chromatography - Mode Poster


Return to Size Exclusion main page
Tosoh Bioscience GmbH Zettachring 6, 70567 Stuttgart, Germany  Tel: +49-711-132570  Email: info.tbg@tosoh.com